Bicon Implant Integrated Abutment Crown Seating
- Surgical suction, 3 cc monojet with NS (normal
saline), 2x2, cotton roll, regular and special q-tip
(2mm vs. 3 mm), alcohol
- X-ray device
- Slow and high speed handpieces, bur block in case for
proximal and occlusal adjustment, polishing disks or cup (prepare, but not
open)
- Instruments:
basic, articulating paper holder, forceps or hemostat to remove abutment or
crown
- Prepare, but
not open the following: syringe, #15, scalpel, periosteal elevator, guiding
pin (2mm vs. 3 mm), sulcus reamers (including 6.5 mm sulcus reamer), curet,
scissors, suture,
- Instruments
needed from Bicon large
implant cassette: mallet, offset or straight threaded handle, seating tip,
seating holding device for anteriors (seating jig, yellow)
- Read Bicon
Restorative Manual p 26: Integrated Abutment Crown (IAC): Seating Technique
or watch video
- Check Bicon
Surgical Manual p 10-17 for arrangement of cassette
- After procedure, brush very well temp abutment, remove
junk, such as calculus, ultrasonicate it, place it in a bag, find the label
and seal
Return to Assistant Page
Xin Wei, DDS, PhD, MS 1st edition 06/1/2011, last revision