Preparation for Impression of Bone-Level Implants
- Several abutment drivers in different length. Short one for the
most posterior tooth with small
mouth
- Abutment removal drivers in case for abutment change
- It is convenient to use a calibrated torque wrench for several implant
case. After torque at 30 Ncm, move to next implant/abutment and later
return to the 1st one at 35 Ncm. But the latch driver appears to
be too long. Therefore the regular wrench should be available.
- In brief, bring the whole plastic box to the treatment room.
Return to
Assistants
Xin Wei, DDS, PhD, MS 1st edition 02/09/2016, last revision