Four days post extraction of 4 of the 1st bicuspids, the
patient returns for bracketing. It appears
easier to place molar bands post extraction than without extraction.
Spaces are larger. Anterior open bite (Fig.1-3) is due to premature
contact of the mesiobuccal cusp of UR7 and the buccal tube at LR 7. To
facilitate LR3 distalization, power chains are placed between LR3 and 6 (Fig.1
.014 niti wires), while tension in LL seems to be too high for power chains
(Fig.3).