Augma, Followed by Collagen Plug
A 27-year-old man returns for #1 and 32 extraction (Fig.1), eight months post #16 and 17 extraction. As usual, no bone substitute is placed in #1 socket after extraction (Fig.7). After #32 extraction, the distal socket looks large so that Augma (Bond Apatite) is placed and pressed (A), followed by a piece of Collagen Plug (C, to prevent Augma (Bone Cement) dissolved by saliva in case premature loss of suture). In fact there is also buccal defect at #32 due to chronic infection and heavy calculus. There is cortical bone formation at #16 socket opening (^). The mesial and distal sockets of #17 (*) seem to be obliterated because of placement of Collagen Plug.
Return to
Plug
Augma
Xin Wei, DDS, PhD, MS 1st edition
09/06/2019, last revision
12/28/2019