One month after implant placement at the sites of #29 and 30, the former is found loose (Fig.1). A: abutment, which was used to hold perio dressing in place.  The patient may have chewed on these abutments.

Retighten & Splint

Xin Wei, DDS, PhD, MS 1st edition 11/16/2014, last revision 11/18/2014