After fine turning, the abutment is fully seated; final round of bone graft (sticky bone) is placed mesiodistally (Fig.5 *) and buccolingually (Fig.6,7).  It appears that there is tight fit between IBS implant and abutment.  It is hoped that the excess bone graft with PRF is able to cover the coronal portion of the implant.  If not, socket preservation should be done in this situation in the future.

Tight Fit     Last     Next

Xin Wei, DDS, PhD, MS 1st edition 02/11/2020, last revision 06/30/2020