Three and a half months postop, a 4.5x5.5(5) mm cemented abutment is placed and torqued to 30 Ncm at #28 after removal of the healing abutment (Fig.3). At the same time, the cemented abutments at #29 and 30 are removed for cleaning and then re-placed and torqued. Note the complete seating of the abutment at #30, as compared to Fig.2. Since the abutment at #29 (5.2x4(3) mm) is subgingival mesially with possible biologic width violation (close to bone graft, Fig.3), it is later changed to 5.2x5.5(4) mm one.
Bone Interference Last Next 骨吸收
Xin Wei, DDS, PhD, MS 1st edition 06/08/2020, last revision 01/08/2021