Immediately Postop | 4 Months Postop | 2 Years 9 Months Postop |
When a 3x14 (4) mm 1-piece implant is being placed, palpation shows no buccal or lingual perforation. The insertion torque is more than 35 Ncm. The 4 mm cuff is chosen because of the thick gingiva. When the implant is further seated (Fig.4), the most coronal thread of the implant is subcrestal except mesially. With bone graft (<), the chance of postop infection due to thread exposure should be low.
He returns 4 months postop without implant thread exposure (Fig.8). With periodic scaling, there appears to be bone regeneration around the implant and the neighboring teeth 2 years 9 months postop (Fig.12). The patient is too busy to start ortho or final restoration.
1-Piece Implant Placed Deep Last Next Xin Wei, DDS, PhD, MS 1st edition 10/06/2016, last revision 10/07/2018