Collagen plug is placed in #32 socket, while allograft and Synthetic bone mixture is placed around the implant (mainly distally, I).  Collagen membrane (M) is placed on the top of the graft, sutures are placed (Fig.6).

Here bone graft is over filled so that the #32 socket cannot be closed completely with the sutures.

Return to Bone Injection

Xin Wei, DDS, PhD, MS 1st edition 09/30/2014, last revision 09/30/2014