A 62-year-old woman will return to take impression for #18 surgical guide ~ 1 month post #14 implant crown temp bond cementation.  Because of short bone, it appears that a 5.5x6.0 mm implant is more appropriate than a 5.0x.7.3 mm one (Fig.1).  The bone density is low; underdrilling is proper (4.5 mm last drill).

5.5x6 mm Last Next

Xin Wei, DDS, PhD, MS 1st edition 11/07/2019, last revision 11/10/2019