Subsequent osteotomy is adjusted so that the apical end of the osteotomy moves distal; when a 3.8x15 mm dummy implant is partially placed, there is clearance (Fig.4). It remains so when a definitive implant is seated (Fig.5); Vanilla graft is placed (Fig.5 *) before placement of a 4.5x5.5(3) mm abutment. More allograft is placed when an immediate provisional is fabricated (Fig.6 arrow and *).
Proximity to Nasal Floor Last Next
Xin Wei, DDS, PhD, MS 1st edition 06/14/2018, last revision 07/12/2018