Miniimplant to be Placed Deep M
Since the 2.5x13 mm implant will be placed deep and palatal at #10, an IS mini implant with 10 mm abutment will be used. Check initial osteotomy with surgical guide to be remove and take PA if needed 3 mm short. If the 2.2x10 mm drill after point one does not engage to the cylinder, use the shorter one. Do not use the last drill for primary stability. Return to Upper Incisor Immediate Implant, Trajectory 位点保存/导板 Xin Wei, DDS, PhD, MS 1st edition 06/14/2019, last revision 11/07/2020