A 3x14(2) mm 1-piece implant is placed with stability; the first round of bone graft is apparently around the apical portion of the implant (Fig.6 *). The coronal end of the implant has to be adjusted several times buccopalatally to accommodate the deep bite. A 2nd round of bone graft following an immediate provisional closes the coronal space of the socket (Fig.7 *).
Graft Before Implant Last Next
Xin Wei, DDS, PhD, MS 1st edition 05/07/2019, last revision 05/08/2019