The corresponding tapered implant (4.5x20 mm) achieves insertion torque > 60 Ncm (Fig.6,7). An abutment is immediately placed (A in Fig.8) to support an immediate provisional. Arrowheads: sinus floor.
Palatally Placed Tapered Implant Last Next
Xin Wei, DDS, PhD, MS 1st edition 12/17/2014, last revision 12/29/2018