Not long postop, the patient called saying that #2 provisional had dislodged. Due to his busy schedule and coronavirus outbreak, he returns nearly 4 months postop. The abutment is distalized and loose with the underlying implant (5x9 mm). The latter is removed before local anesthesia (Fig.1 distal defect).
Implant Failure Last Next Xin Wei, DDS, PhD, MS 1st edition 06/01/2020, last revision 06/02/2020