Another drawback of this case is that the implant is not placed deep enough (Fig.5: 3 months postop). When a crown is cemented 1 year 4 months postop, the distal coronal portion of the implant is supragingival, although there is no infection.
Return to Overexpansion Last Next
Xin Wei, DDS, PhD, MS 1st edition 11/18/2014, last revision 09/30/2018